Waterwatch Data Portal
EG_MIT530 Mitchell River - Hillside, on Nick Bartons property
23 September 2011
Site visit details
Overview
Catchment | Mitchell River |
---|---|
Site | Mitchell River - Hillside, on Nick Bartons property EG_MIT530 |
Date and Time | Friday 23rd September 2011 09:00am |
Approved | Approved |
Physical Chemical Tests
D.O. % | D.O mg/L | EC µS/cm | pH pH Units | rP mg/L P | Air ° C | Water ° C | P mg/L | Turb NTU | |
---|---|---|---|---|---|---|---|---|---|
Sample | 67 | 7 | 0.08 | 13.5 | 15.5 | 9 |
Weather | cloudy |
---|---|
Last rainfall | During the last week 12 |
Flow estimate | Moderate |
Water Appearance | Clear |
Stream depth | |
Stream width | |
Hazards | |
Litter/Pollutants |
Phosphorus reading not totally repeatable - moved about .02 - .03 EC calibrated on 1413, but check on 84 standard read as 69 - possibly correct reading was 82 pH Meter misread 7.00 calibration sample as 5.99. Water sample also read 5.99 Recalibrated meter on 7.00 sample - read 7.02, then dropped to 6.99. Water sample read 7.05. Rechecked on calibration sample - meter now read 7.35. As first readings of calibration standard and water sample were identical I have assumed water PH was 7.00.
All content, files, data and images provided by the Waterwatch Data Portal and Gallery are subject to a Creative Commons Attribution License
Content is made available to be used in any way, and should always attribute Waterwatch and www.vic.waterwatch.org.au