Waterwatch Data Portal
Site visit details
Overview
Catchment | Lake Corangamite |
---|---|
Site | Mundy Gully Farm Crossing CO_MGC010 |
Date and Time | Saturday 23rd June 2018 16:00pm |
Approved | Approved |
Physical Chemical Tests
D.O. % | D.O mg/L | EC µS/cm | pH pH Units | rP mg/L P | Air ° C | Water ° C | Turb NTU | |
---|---|---|---|---|---|---|---|---|
Sample | 85 | 9.6 | 9580 | 8.4 | 0 | 11.7 | 8.6 | 9 |
Weather | overcast |
---|---|
Last rainfall | More than a week ago 40.00 |
Flow estimate | POOLS: No continuous flow in channel and intermittent pools (in-stream habitats not connected) |
Water Appearance | Clear |
Stream depth | 1m - 2m |
Stream width | 2m - 5m |
Hazards | |
Litter/Pollutants |
all Mundy Gully and Browns Waterholes test complete by Shari McConachy are still using the Visocolor Phosphat test (DEV) so are measured in mg/L P