Waterwatch Data Portal
NE_OVE004 Ovens River East Branch Bon Accord Track, Harrietville
24 September 2018
Overview
Catchment | Ovens River |
---|---|
Site | Ovens River East Branch Bon Accord Track, Harrietville NE_OVE004 |
Date and Time | Monday 24th September 2018 12:00pm |
Approved | Approved |
Physical Chemical Tests
D.O. % | D.O mg/L | EC µS/cm | pH pH Units | rP mg/L P | Water ° C | Turb NTU | |
---|---|---|---|---|---|---|---|
Sample | 52.79 | 4.4 | 68.9 | 7.86 | 0.017 | 9.6 | 9 |
Weather | sunny |
---|---|
Last rainfall | More than a week ago |
Flow estimate | MEDIUM: flow is normal/typical average flow |
Water Appearance | Clear |
Stream depth | 51cm - 99cm |
Stream width | > 5m |
Hazards | |
Litter/Pollutants |
The calculated % oxygen saturation is 52.79% but if you use the saturation monogram the result is 40%. This is a big difference! Using the web calculator at http://www.hbuehrer.ch/Rechner/O2satur.html using an elevation of 500 masl I get 41.13%
I think the % saturation calculator needs checking or an explanation is required for the difference.
Salinity meter is not accurate and has been sent away for inspection.
Simon Law