Waterwatch Data Portal
ME_EMI150 Main Creek at Shands Rd crossing
6 August 2010
Site visit details
Overview
Catchment | Bunyip River |
---|---|
Site | Main Creek at Shands Rd crossing ME_EMI150 |
Date and Time | Friday 6th August 2010 11:00am |
Approved | Approved |
Physical Chemical Tests
Ammon-Nit mg/L NH3-N | N mg/L NH4+ | D.O. % | D.O mg/L | EC µS/cm | FrP mg/L P | Nitrate-Nit mg/L N | pH pH Units | rP mg/L P | Air ° C | Water ° C | Turb NTU | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Sample | 0 | 89.06 | 10 | 900 | 4.4 | 0.02 | 13 | 10.1 | 10 |
Weather | overcast |
---|---|
Last rainfall | During the last 24 hours 70.00 |
Flow estimate | FLOOD / OVERBANK: flow is high and water level has exceeded bank capacity and is connecting with floodplain |
Water Appearance | Clear |
Stream depth | Other:43 cm |
Stream width | Other:2.4 m |
Hazards | |
Litter/Pollutants |
Water over ford: 6 m wide, ankle deep
Low pH may be due to recent calibration; to be monitored
Conductivity due to particularly good flushing of creek and catchment; reading might be expected
All content, files, data and images provided by the Waterwatch Data Portal and Gallery are subject to a Creative Commons Attribution License
Content is made available to be used in any way, and should always attribute Waterwatch and www.vic.waterwatch.org.au