Waterwatch Data Portal
NC_SHE950 Shepherds Hut Creek, Shepherds Hill Road, Lauriston
22 March 2020
Site visit details
Overview
Catchment | Campaspe River |
---|---|
Site | Shepherds Hut Creek, Shepherds Hill Road, Lauriston NC_SHE950 |
Date and Time | Sunday 22nd March 2020 12:30pm |
Approved | Approved |
Physical Chemical Tests
EC µS/cm | pH pH Units | rP mg/L P | Air ° C | Water ° C | Turb NTU | |
---|---|---|---|---|---|---|
Sample | 511 | 6.9 | 24.5 | 18.9 | 30 |
Weather | cloudy |
---|---|
Last rainfall | During the last week |
Flow estimate | POOLS: No continuous flow in channel and intermittent pools (in-stream habitats not connected) |
Water Appearance | Stained brown,Muddy |
Stream depth | 0 - 50cm |
Stream width | < 2m |
Hazards | |
Litter/Pollutants |
The spot I had been tesitng which is upstream of a large log over creek, was nearly dry last time and completely dry this time. I ahve decided to move my tsting spot a few metres downstream to the other side of the log where a pool has persisted. Hope thats OK
Also water too brown to test phosphorous, I did try, so have deleted that test
All content, files, data and images provided by the Waterwatch Data Portal and Gallery are subject to a Creative Commons Attribution License
Content is made available to be used in any way, and should always attribute Waterwatch and www.vic.waterwatch.org.au