Site visit details

Overview

Catchment Campaspe River
Site Stony Creek at Trentham Golf Course NC_STO950
Date and Time Thursday 4th February 2021 15:15pm
Approved Approved

Notes

Physical Chemical Tests

EC µS/cm pH pH Units rP mg/L P Air ° C Water ° C Turb NTU
Sample 105 7.2 0.03 23.7 21.9 9
Weather overcast
Last rainfall During the last week 72.30
Flow estimate LOW: Minimum flow in channel/continuous flow in some part of channel (in-stream habitats connected)
Water Appearance Clear
Stream depth 0 - 50cm
Stream width 2m - 5m
Hazards Bit overgrown and rough
Litter/Pollutants

Before going to this site, which I usually do first, I sampled and measured all parameters (with special attention to Reactive P) on the Stoney Creek at the Trentham High Street bridge.

Air temp 24.3 C; Water temp < 20 C; EC 72; pH 6.9; turbidity < 9.

Reactive P 1st reading > 0.25

Reactive P 2nd reading 0.03

Re the P readings, what this seems to say is that I will need in future to clean the test solution tube and cap really well before the first sample (even though I clean this tube after each use) and will need to take two readings if the first reading is high. Of course, the above results also cast doubt on all the previously recorded high P readings.