Site visit details

Overview

Catchment Latrobe River
Site TYERS RIVER at Wirilda Reserve off Tyers- Yallourn Nth Rd. WG_TYR090
Date and Time Thursday 16th March 2023 09:45am
Approved Approved

Notes

Physical Chemical Tests

D.O mg/L EC µS/cm Nitrate-Nit mg/L N pH pH Units rP mg/L P Air ° C Water ° C Turb NTU
Sample 100 4 0.015 19.1 21.4 10
Weather cloudy
Last rainfall During the last week 10.00
Flow estimate
Water Appearance Clear
Stream depth 1m - 2m
Stream width > 5m
Hazards
Litter/Pollutants

Despe repeated attempts, we could not successfully calibrate the EC meter.  This is the second time that this has failed us and we believe it is in need of replacement.  Tash could you provide Peter Bray with a new meter at the Bendigo  Awards Ceremony? Although we could not calibrate  we nevertheless tested the sample and obtained a result of 100 which is average for the site.

It is worth noting that our pH reading of 4.0 was well outside the normal range.  The meter calibrated successfully and we repeated the finding so had to accept it as correct.

Diary photos

No diary entries recorded for this visit

Creative Commons CC BY
All content, files, data and images provided by the Waterwatch Data Portal and Gallery are subject to a Creative Commons Attribution License

Content is made available to be used in any way, and should always attribute Waterwatch and www.vic.waterwatch.org.au