Waterwatch Data Portal
ME_YAR580 Arthurs Creek, near Bridge, Arthurs Creek Road, Arthurs Creek
20 July 2012
Site visit details
Overview
Catchment | Yarra River |
---|---|
Site | Arthurs Creek, near Bridge, Arthurs Creek Road, Arthurs Creek ME_YAR580 |
Date and Time | Friday 20th July 2012 09:30am |
Approved | Approved |
Physical Chemical Tests
Ammon-Nit mg/L NH3-N | N mg/L NH4+ | D.O. % | D.O mg/L | EC µS/cm | FrP mg/L P | Nitrate-Nit mg/L N | pH pH Units | rP mg/L P | Air ° C | Water ° C | Turb FTU | Turb NTU | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sample | 0 | 10 | 250 | 6.9 | 0.02 | 10 | 10 | 27 |
Weather | overcast |
---|---|
Last rainfall | During the last week 9.5 |
Flow estimate | MEDIUM: flow is normal/typical average flow |
Water Appearance | Stained brown |
Stream depth | 0 - 50cm |
Stream width | 13 |
Hazards | nil |
Litter/Pollutants |
Julia, suggested (during annual shadow sampling undertaken) we at YAR 580 should have a Digital Turbidity Meter. The dissolved Oxygen Test gave a 90% percent saturation of oxygen. a new Digital air and water temp gauge provided, will be used in future. Discussion re the timing of the pH meter in the water sample -- the 10 second rule? or even longer, and the difference in the readings from the two meters on this site at the above date.